438
Rockwell Automation Publication 1783-UM007I-EN-P - December 2017
Appendix D
Cables and Connectors
Alarm Ports
The front-panel alarm-relay connector ports are described in the following
illustration and table.
Figure 71 - Wiring Example for Alarm Inputs and Outputs
PoE Port Cable Specifications
For PoE ports, use a Category 5 (Cat 5) cable with a distance of up to 100 m
(328 ft).
Alarm
Relay
Coil
Alarm Input 2
Alarm Input 1
User-supplied contact closure
generates external alarms.
1
2
3
4
5
6
To Alarm Input
+24V DC from User
To Alarm Input
Alarms Connector
NO
COM
NC
IN2
REF
IN1
Label
Connection
NO
Alarm Output Normally Open (NO) connection
COM
Alarm Output Common connection
NC
Alarm Output Normally Closed (NC) connection
IN2
Alarm Input 2
REF
Alarm Input Reference Ground connection
IN1
Alarm Input 1