Rockwell Automation Publication 1783-UM007I-EN-P - December 2017
27
Get Started
Chapter 2
Before you begin, do the following:
•
Single-mode Express Setup or multi-mode Express Setup in Short Press
mode:
–
Disable other networks in your system.
–
Set your computer to determine its IP address automatically versus
statically.
–
Disable static DNS servers.
•
Disable any wireless interface on your computer.
•
Disable browser proxy settings.
•
Make sure at least one switch Ethernet port is available for Express
Setup.
•
For Stratix 5700 or ArmorStratix 5700 switches, make sure that the
SD card is
not
inserted.
Express Setup Button
Use the Express Setup button on the physical switch to perform Express Setup.
This Express Setup button is recessed behind the panel. To reach the button,
use a small tool, such as a paper clip.
IMPORTANT
For catalog numbers 1783-BMS4S2SGL and 1783-BMS4S2SGA, you
must use port Gi1/1 for Express Setup.
Do not use the console port for Express Setup.
WARNING:
When you press the Express Setup button while power is on, an
electric arc can occur. This could cause an explosion in hazardous location
installations.