Configure Switch Features
Chapter 3
Table 71 - Single Translation
Field
Description
Type of Entry
Choose Single. Single is the default value.
Starting Public IP Address
Type the existing address for the device on the public subnet.
Starting Private IP Address
Type a unique private address to represent the device.
Effective Public Addresses
Displays the existing address for the device on the public subnet that is configured for translation.
If blank, verify that the values in the preceding fields are valid.
Effective Private Addresses
Displays the unique private address to represent the device.
If blank, verify that the values in the preceding fields are valid.
Table 72 - Range Translation
Field
Description
Type of Entry
Choose Range.
Starting Public IP Address
Type the existing starting address for the device on the public subnet.
Starting Private IP Address
Type a unique, starting private address to represent the devices.
Range
Type the number of addresses to include in the range.
Valid values: 2…128
Default value = 1
IMPORTANT:
Each address in the range counts as one translation entry. The switch supports a maximum of 128 translation entries.
Effective Public Addresses
Displays the range of existing addresses for devices on the public subnet that are configured for translation.
If blank, verify that the values in the preceding fields are valid.
Effective Private Addresses
Displays the range of unique private addresses to represent the devices.
If blank, verify that the values in the preceding fields are valid.
Table 73 - Subnet Translation
Field
Description
Type of Entry
Choose Subnet.
Starting Public IP Address
Type the existing starting address for a device on the public subnet. This address must correspond to the size of the subnet mask to translate.
Subnet Mask
Starting Public Subnet Address
255.255.0.0
The last two octets must end in 0.
EXAMPLE:
10.200.0.0
255.255.255.0
The last octet must end in 0.
EXAMPLE:
10.200.1.0
255.255.255.128
The last octet must end in 0 or 128.
EXAMPLE:
10.200.1.0 or 10.200.1.128
255.255.255.192
The last octet must end in one of the following: 0, 64, 128, 192.
EXAMPLE:
10.200.1.64
255.255.255.224
The last octet must end in one of the following: 0, 32, 64, 96, 128, 160, 192, 224.
EXAMPLE:
10.200.1.32
255.255.255.240
The last octet must end in one of the following: 0, 16, 32, 48, 64, 80, 96, 112, 128, 144, 160, 176, 192,
208, 224, 240.
EXAMPLE:
10.200.1.16
Summary of Contents for armorstratix 5700
Page 10: ...10 Rockwell Automation Publication 1783 UM007I EN P December 2017 Table of Contents Notes ...
Page 12: ...12 Rockwell Automation Publication 1783 UM007I EN P December 2017 Preface Notes ...
Page 72: ...72 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 2 Get Started Notes ...
Page 396: ...396 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix A DataTypes Notes ...
Page 457: ......