Rockwell Automation Publication 1783-UM007I-EN-P - December 2017
183
Configure Switch Features
Chapter 3
Table 66 - Range Translation
Field
Description
Type of Entry
Choose Range.
Starting Private IP Address
Type the existing starting address for the device on the private subnet.
Starting Public IP Address
Type a unique, starting public address to represent the device.
Range
Type the number of addresses to include in the range.
Valid values: 2…128
Default value = 1
IMPORTANT:
Each address in the range counts as one translation entry. The switch supports a maximum of 128 translation
entries.
Effective Private Addresses
Displays the range of existing addresses for devices on the private subnet that are configured for translation.
If blank, verify that the values in the preceding fields are valid.
Effective Public Addresses
Displays the range of unique public addresses to represent the devices.
If blank, verify that the values in the preceding fields are valid.
Table 67 - Subnet Translation
Field
Description
Type of Entry
Choose Subnet.
Starting Private IP Address
Type the existing starting address for a device on the private subnet. This address must correspond to the size of the subnet mask to translate.
Subnet Mask
Starting Private Subnet Address
255.255.0.0
The last two octets must end in 0.
EXAMPLE:
192.168.0.0
255.255.255.0
The last octet must end in 0.
EXAMPLE:
192.168.1.0
255.255.255.128
The last octet must end in 0 or 128.
EXAMPLE:
192.168.1.0 or 192.168.1.128
255.255.255.192
The last octet must end in one of the following: 0, 64, 128, 192.
EXAMPLE:
192.168.1.64
255.255.255.224
The last octet must end in one of the following: 0, 32, 64, 96, 128, 160, 192, 224.
EXAMPLE:
192.168.1.32
255.255.255.240
The last octet must end in one of the following: 0, 16, 32, 48, 64, 80, 96, 112, 128, 144, 160, 176, 192, 208, 224,
240.
EXAMPLE:
192.168.1.16
Starting Public IP Address
Type a unique, starting public address to represent the devices. This address must correspond to the size of the subnet mask to translate.
Subnet Mask
Starting Public Subnet Address
255.255.0.0
The last two octets must end in 0.
EXAMPLE:
10.200.0.0
255.255.255.0
The last octet must end in 0.
EXAMPLE:
10.200.1.0
255.255.255.128
The last octet must end in 0 or 128.
EXAMPLE:
10.200.1.0 or 10.200.1.128
255.255.255.192
The last octet must end in one of the following: 0, 64, 128, 192.
EXAMPLE:
10.200.1.64
255.255.255.224
The last octet must end in one of the following: 0, 32, 64, 96, 128, 160, 192, 224.
EXAMPLE:
10.200.1.32
255.255.255.240
The last octet must end in one of the following: 0, 16, 32, 48, 64, 80, 96, 112, 128, 144, 160, 176, 192, 208, 224,
240.
EXAMPLE:
10.200.1.16
Summary of Contents for armorstratix 5700
Page 10: ...10 Rockwell Automation Publication 1783 UM007I EN P December 2017 Table of Contents Notes ...
Page 12: ...12 Rockwell Automation Publication 1783 UM007I EN P December 2017 Preface Notes ...
Page 72: ...72 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 2 Get Started Notes ...
Page 396: ...396 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix A DataTypes Notes ...
Page 457: ......