![AIXTRON CRIUS II System Manual Download Page 149](http://html1.mh-extra.com/html/aixtron/crius-ii/crius-ii_system-manual_2883093149.webp)
AIXTRON
- Dokumentation
CONFIDENTIAL
149
6
cr
ius_I
I_e
n_
00,
Ed
it
io
n
06/
201
0
System Manual
Maintenance
CRIUS II
Main power supply
6.7
Main power supply
6.7.1
Hazard alerts
Maintenance and service personnel working on the electrical equipment must
pay special attention to the following safety notes.
6.7.2
Checking the main switch
Checking the remote
control switching
function
1
Check the switching function of the main switch remote control.
Fig. 6-5
Remote control for the main switch
WARNING!
Hazardous voltage.
The system contains parts which carry dangerous levels of voltage.
Touching these parts will cause an electric shock. The shock may be
lethal.
Prior to any work in the danger area:
•
Lock out and tag out the main power supply
•
Ground the equipment
•
Check to make sure that no one is in the danger area before you
switch the system on again
NOTE:
Only personnel who have completed electrotechnical professional train-
ing are permitted to perform work on the electrical equipment.
NOTE:
Maintenance and service on the electrical equipment requires no type 4
tasks.