Making Measurements
5
6000 Series Oscilloscope User’s Guide
225
Spectral Leakage
The FFT operation assumes that the time record repeats. Unless
there is an integral number of cycles of the sampled waveform
in the record, a discontinuity is created at the end of the record.
This is referred to as leakage. In order to minimize spectral
leakage, windows that approach zero smoothly at the beginning
and end of the signal are employed as filters to the FFT. The FFT
menu provides three windows: Hanning, flattop, and
rectangular. For more information on leakage, see Agilent
Application Note 243, “The Fundamentals of Signal Analysis” at
http://cp.literature.agilent.com/litweb/pdf/5952-8898E.pdf
.
FFT Operation
1
Press the
Math
key, then press the
FFT
softkey to display the
softkeys for FFT settings.
•
Source
— selects the source for the FFT. The source can be
any analog channel, or math functions 1 + 2, 1 – 2, and
1 * 2.
•
Span
— sets the overall width of the FFT spectrum that you
see on the display (left to right). Divide span by 10 to
calculate the number of Hertz per division. It is possible to
set Span above the maximum available frequency, in
which case the displayed spectrum will not take up the
whole screen. Press the
Span
softkey, then turn the Entry
knob to set the desired frequency span of the display.
Source
select
Frequency
Span
Center
frequency
Preset Span
and Center
frequencies
Vertical and
Window FFT
controls
Sample
rate
Summary of Contents for InfiniiVision 6000 Series
Page 1: ...Agilent Technologies Agilent InfiniiVision 6000 Series Oscilloscopes User s Guide ...
Page 60: ...60 6000 Series Oscilloscope User s Guide 1 Getting Started ...
Page 126: ...126 6000 Series Oscilloscope User s Guide 3 Viewing and Measuring Digital Signals ...
Page 292: ...292 6000 Series Oscilloscope User s Guide 6 Displaying Data Interpreting Decoded LIN Data ...
Page 314: ...314 6000 Series Oscilloscope User s Guide 6 Displaying Data ...
Page 354: ...354 6000 Series Oscilloscope User s Guide 8 Reference ...
Page 362: ...362 6000 Series Oscilloscope User s Guide 9 ...