80
Agilent E8462A Relay Multiplexer Command Reference
three hexidecimal displays which show the values of the two Tree registers and the
Analog Bus register. For example, assume FUNCtion is set to WIRE4 and channel
35 is closed (this also closes tree relays T4 and T11 connecting the 4-wire channel
35 to Terminals 0, 1, 4 and 5). The display would be:
“B0: #H0000 B1: #H0000 B4: #H0008 B5: #H0000 T0: #H0810 T1: #H0000 An: #H0000”
where the hexidecimal value 0008 for B4 indicates channel 3 in bank 4 is closed
(channel 3 in bank 6 is paired with this channel and is also closed). The hexidecimal
value 0810 for T0 (the Tree bank 0 register) indicates the T4 and T11 tree relays are
closed connecting channel 3 of bank 4 to Terminal lines 0 and 1 and channel 3 of
bank 6 to Terminal lines 4 and 5.
Example
Enabling the Monitor Mode
DISP:MON:CARD 2
Select module #2 in a switchbox
DISP:MON 1
Turn the monitor mode on
DISPlay:MONitor[:STATe]?
DISPlay:MONitor[:STATe]?
queries the monitor mode state to determine if it is set
to ON or OFF.