Table 3-3. Agilent E8462A SCPI Command Quick Reference.
Command
Description
ABORt
Abort a scan in progress.
ARM
:COUNt
<
number>
MIN|MAX
:COUNT? [MIN|MAX]
Multiple scans per INIT command.
Query number of scans.
DIAGnostic
:FUSE?
<
card_number>
:INTerrpt[:LINE]
<
card_number>,<line_number>
:INTerrpt[:LINE]?
<
card_number>
:INTerrpt:TIMer
<
card_number>,<time>
:INTerrupt:TIMer?
<
card_number>
:
SCAN:DELay
<
card_number>,<time>
:
SCAN:DELay?
<
card_number>
Query fuse continutity.
Set interrupt line of multiplexer.
Query interrupt line.
Set wait time after an open or close before interrupt.
Query interrupt time.
Set additional scan delay time.
Query scan delay time.
DISPlay
:MONitor:CARD <
card_number
> | AUTO
:MONitor:CARD?
:MONitor[:STATe] <
mode
>
:MONitor[:STATe]?
Selects a switchbox module to be monitored.
Queries the card monitor setting.
Sets the monitor state.
Quries the monitor state setting.
INITiate
:CONTinuous ON|OFF|1|0
:CONTinuous?
[:IMMediate]
Enables/Disables continuous scanning.
Query continuous scan state.
Starts a scanning cycle.
OUTPut
:ECLTrg
n
[:STATe] ON|OFF|1|0
:ECLTrg
n
[:STATe]?
[:EXTernal][:STATe] ON|OFF|1|0
[:EXTernal][:STATe]?
:TTLTrg
n
[:STATe] ON|OFF|1|0
:TTLTrg
n
[:STATe]?
Enables/Disables ECL Trigger bus line pulse.
Query ECL Trigger bus line state.
Enables/Disables "Trig Out" pulse.
Query port enable state.
Enables/Disables TTL Trigger bus line pulse.
Query TTL Trigger bus line state.
[ROUTe:]
CLOSe
<
channel_list>
CLOSe?
<
channel_list>
FUNCtion
<
card_number>,<function>
FUNCtion?
<
card_number>
OPEN
<
channel_list>
OPEN?
<
channel_list>
SCAN
<
channel_list>
SCAN:MODE
<
mode>
SCAN:MODE?
SCAN:PORT
<
port>
SCAN:PORT?
Close channel(s).
Query channel(s) closed.
Set operating mode.
Query operating mode.
Open channel(s).
Query channel(s) opened.
Define channels for scanning.
Set scan mode.
Query scan mode.
Select Analog Bus.
Query Analog Bus state.
STATus
:OPERation:CONDition?
:OPERation:ENABle
<
number>
:OPERation:ENABle?
:OPERation[:EVENt]?
:PRESet
Returns status of Condition register.
Enables events in the Event register to be reported.
Returns which bits in the Event register are unmasked.
Returns which bits in the Event register are set.
Sets Enable register bits to 0.
SYSTem
:CDEScription?
<
number>
:CPON
<
number
>
|ALL
:CTYPe?
<
number>
:ERRor?
Returns description of module in switchbox.
Sets specified module in a switchbox to power-on state.
Returns the module type.
Returns error number/message to error queue.
TRIGger
[:IMMediate]
:SLOPe
<
slope>
:
SLOPe?
:SOURce BUS
:SOURce ECLTrg
n
:SOURce EXTernal
:SOURce HOLD
:SOURce IMMediate
:SOURce TTLTrg
n
:SOURce?
Causes a trigger to occur.
Select negative polarity of the output trigger.
Query polarity of the output trigger.
Trigger source is *TRG.
Trigger source is ECL Trigger bus line 0 or 1.
Trigger source is "Trig In" port.
Hold off triggering.
Continuous (internal) triggering.
Trigger source is TTL Trigger bus line (0-7).
Query current trigger source.
Summary of Contents for E8462A
Page 2: ...x...
Page 10: ...8 Notes...
Page 11: ...9 Notes...
Page 12: ...10 Notes...
Page 15: ...Configuring the Agilent E8462A Multiplexer 13 Figure 1 1 Agilent E8462A Simplified Schematic...
Page 68: ...66 Using the Multiplexer...
Page 104: ...102 Agilent E8462A Relay Multiplexer Command Reference...
Page 118: ...116 Agilent E8462A Relay Multiplexer Command Reference...
Page 126: ...124 Agilent E8462A Scanning Voltmeter Application Examples Chapter 4 Notes...
Page 146: ...144 Register Based Programming...
Page 156: ...154 Index...