3-46
Programming
Lists of Commands
:CALCulate3:FPERot:POWer:[WAVelength]?
Queries the power wavelength of the selected modes.
I
:CALCulate3:FPERot:POWer:FREQuency?
Queries the power frequency of the selected modes.
I
:CALCulate3:FPERot:POWer:WNUMber?
Queries the power wavenumber of the selected modes.
I
:CALCulate3:FPERot:SIGMa:[WAVelength]?
Queries the sigma wavelength of the selected modes.
I
:CALCulate3:FPERot:SIGMa:FREQuency?
Queries the sigma frequency of the selected modes.
I
:CALCulate3:FPERot:SIGMa:WNUMber?
Queries the sigma wavenumber of the selected modes.
I
:CALCulate3:POINts?
Queries the number of points in the data set.
I
:CALCulate3:PRESet
Turns off any CALCulate3 calculation that is on.
I
:CALCulate3:SNR:AUTO
Selects the internal or externally entered frequency value
for the noise measurement reference in the SNR
calculation.
I
:CALCulate3:SNR:REFerence:FREQuency
Sets the frequency used for the noise measurement
reference in the SNR calculation.
I
:CALCulate3:SNR:REFerence[:WAVelength]
Sets the wavelength used for the noise measurement
reference in the SNR calculation.
I
:CALCulate3:SNR:REFerence:WNUMber
Sets the wave number used for the noise measurement
reference in the SNR calculation.
I
:CALCulate3:SNR[:STATe]
Turns the SNR calculation on and off.
I
DISPlay Subsystem
:DISPlay:MARKer:MAXimum
Sets the marker to the signal with the largest power.
I
:DISPlay:MARKer:MAXimum:LEFT
Moves marker to signal with the next lower wavelength or
frequency.
I
:DISPlay:MARKer:MAXimum:NEXT
Moves the marker to the signal with the closest power
level just below the power level of the signal at the current
marker position.
I
:DISPlay:MARKer:MAXimum:PREVious
Moves the marker to the signal with the closest power
level just above the power level of the signal at the current
marker position.
I
:DISPlay:MARKer:MAXimum:RIGHt
Moves marker to the next higher wavelength or frequency.
I
:DISPlay[:WINDow]:GRAPhics:STATe
Turns the instrument display of the power bars on and off.
S
HCOPy Subsystem
:HCOPy:IMMediate
Starts a printout.
S
SENSe Subsystem
:SENSe:CORRection:DEVice
Configures wavelength measurements for narrowband or
wideband devices.
I
Table 3-10. Programming Commands (4 of 5)
Command
Description
Code
Codes: S indicates a standard SCPI command. I indicates an instrument specific command.
Summary of Contents for 86120C
Page 12: ......
Page 26: ...1 14 Getting Started Returning the Instrument for Service ...
Page 27: ...1 15 Getting Started Returning the Instrument for Service ...
Page 28: ......
Page 96: ...3 18 Programming Monitoring the Instrument ...
Page 128: ...3 50 Programming Lists of Commands ...
Page 236: ...4 108 Programming Commands UNIT Subsystem ...
Page 248: ......
Page 264: ...6 16 Specifications and Regulatory Information Product Overview ...
Page 269: ...7 5 Reference Menu Maps Appl s Menu ...
Page 271: ...7 7 Reference Menu Maps Display List by WL Menu Delta On Menu ...
Page 273: ...7 9 Reference Menu Maps System Print Menu ...
Page 274: ...7 10 Reference Menu Maps System Setup Menu ...
Page 284: ......
Page 292: ......
Page 293: ......