With these configurations, the individual commands are addressed with the following
addresses and command lengths.
Address
Command
lengths
Command
200
1 Byte
Load Config Number
201
2 Byte
Aux Power Output
203
1 Byte
Controller Restart
204
1 Byte
AutoMode:
205
1 Byte
General Release
206
2 Byte
Direction
208
2 Byte
Intensity
In addition to the "standard" inputs/outputs described in the previous section, there are
still other commands. However, these are not required for the normal operation of the
aflex. In the following, all fieldbus inputs/outputs are listed and briefly described.
6.6.5 Input commands
All fieldbus inputs can be defined via "alexConfigurator". In the data range and also
data position. The suggested range of data listed in the table below gives the original
data range of the command, but all commands can be stretched or compressed to any
data range. The target module tells which module of the aflex control the command is
directed to. Thus, e.g. the aflex controlled via the target module "aflex module". The
control unit via the target module "control unit".
Table 12: Input commands
Target mod-
ule
Designa-
tion:
Description
Native
data
range
Control Unit: AutoMode: Possibility to switch between automatic/man-
ual mode. Manual mode: Parameters can only
be changed via the "aflexConfigurator". Auto-
matic mode: Parameters can only be changed
via the fieldbus interface. If the Configurator is
connected, the operating mode cannot be
switched via the fieldbus.
1 Bit
Control Unit: General
Release
Release for the control of aflex. If the release
is not available, no power outputs are
switched.
1 Bit
Control Unit: Load Con-
fig Number
Load a saved configuration
8 Bit