Page 20
2017-01-13
Release: 02.0
Use the original countersunk-head screws.
Observe that maximum torque of this countersunk head screw for fixing
of aflex on the adaptor plate:
2.9 Nm
Figure 8: Assembly of the adaptor plate
Connection of the device
The actuator of aflex is connected via the 16-pole sockets on the bottom side.
Use the delivered connection cable with the corresponding connector for it.
The back lighting is connected over the three-pole connector.
Further information for pin assignment is found in the circuit diagram. This is included
in the appendix.
Power supply
WARNING
Work on the electrical supply may only be carried out by
trained, authorized qualified personnel!
The grid feed must take place on the customer's side via a
residual current circuit breaker!
Aflex may only be operated with power supply mentioned
on the name plate!
The energy feed of aflex takes place with 24V DC low-voltage. The energy supply must
be made available by the operator. The manufacturer recommends a 10 amp slow fuse
or a circuit breaker of the C 10A characterization.
The exact specification is available in the chapter
The assembly may only be carried out by a qualified personnel.
Pay at-
tention
to the ca-
ble
!