6.6.2 Digital input/output
The control unit has eight 24V DC digital inputs and outputs. The following figure shows
an integration to a "customer device".
Figure 71: Digital IO Connection
In contrast to other fieldbus interfaces, the "load config #" command must be used
instead of the "load config number" command to load a configuration using the digital
IO.
Table 8: Digital IO Commands
Command name
Description
Load Config #1
Load Config #2
Load Config #3
Load Config #4
Load Config #5
In the control unit various aflex configurations can be stored.
This allows you to quickly switch between separating, con-
veying or alternatively changing configurations for different
work pieces.
With the commands Load Config #x, the corresponding con-
figuration is loaded with a rising flank. These commands al-
low you to load a configuration without using 8 bits for the
LoadConfigNumber command.
24V
Output
24V
Input
LED - actual
states
Control
Unit