![Aegis OSC-9200 User Manual Download Page 114](http://html1.mh-extra.com/html/aegis/osc-9200/osc-9200_user-manual_2860410114.webp)
99
CAN Trigger
Trigger Conditions
l
Start
— the oscilloscope will be triggered at the start bit of a frame.
l
Remote
— the oscilloscope will be triggered by a remote frame with specified ID.
l
ID
— the oscilloscope will be triggered by a frame with specified ID.
l
ID+DATA
— the oscilloscope will be triggered by data frame that have specified ID and data.
l
Error
— the oscilloscope will be triggered by an error frame.
Operation Steps
1.
Press the
Trigger Setup
to enter the
TRIGGER
function menu.
2.
Press the
Type
and select
Serial
.
3.
Press
Protocol
and select
CAN
.
4.
Press
Trigger Setting
to enter the
CAN TRIG SET
menu.
5.
Press
Condition
and select the trigger condition by
Universal Knob
:
l
If you select the
REMOTE
and
ID
condition:
a.
Press
ID
Bits
to set the length of ID (11bits or 29 bits).
b.
Press
Curr ID Byte
and use the
Universal Knob
to select the byte that you want to set.
c.
Press
ID
and set the ID’s value by the
Universal Knob
.
(
Tips
: For convenience, the ID is split into several bytes. For example, if the ID’s length is 11
bits, it will be split into two bytes, a byte includes 8 bits. If “1st byte” is selected, only the 8
least significant bits can be changed.)
l
If you select the
ID+DATA
condition:
a.
Press the
ID bits
F key to select the ID’s length (11 or 29 bits).
b.
Press the
Curr ID Byte
F key and use
Universal Knob
to select the byte that you want
to modify.
c.
Press the
ID
F key and set the ID’s value by
Universal Knob
.
d.
Press the
Data
F key and set the value of the first byte by
Universal Knob
.
Summary of Contents for OSC-9200
Page 1: ...AEGIS Shaft Voltage Tester Handheld Digital Oscilloscope AEGIS OSC 9200...
Page 18: ...3 Appearance and Dimensions mm Figure 1 Front View Figure 2 Side view...
Page 44: ...29 Horizontal Control Contents u Horizontal Scale u Horizontal Delay u Roll Mode u Zoom Mode...
Page 56: ...41 Figure 16 x Interpolation Figure 17 Sinx x Interpolation...
Page 60: ...45 Figure 21 With Random Noise Normal Mode Figure 22 With Random Noise Average Mode...
Page 105: ...90...
Page 135: ...120 Figure 75 Integral with Offset...
Page 139: ...124 Figure 77 Measure Pulse Width...
Page 190: ...175 DC Current Measurement AC Current Measurement...