E 750
Primary pump maintenance
GB
002
3
9
-
E
d
itio
n
04
-
D
ecem
b
er
05
The frequency of preventive maintenance is listed
D 100
Components:
ALCATEL 200 Oil (1 liter)
Cartridge (Oil mist eliminator).....................................
F 600
For best performance, check the oil level in the sight glass
periodically.
Check the oil level of
the roughing pump
If the level is not between the
mini and the maximum level, it is
necessary to add oil.
Maxi.
Mini.
Oil for the first utilisation is delivered with the detector.
B 110).
Replacement of oil is the user’s responsability.
The Alcatel pumps are tested with ALCATEL 200 oil.
Their specifications are guaranteed only when this
recommended lubricant is used.
Add oil
Open the cover (ASM 142).
Remove the cover (ASM 142 S).
Remove the draining plugs.
ASM 142 S
ASM 142
/3