Communication profiles
32
Figure 4. State machine, DSP 402 communication profile
CW: xxxxxxxx1xxxxxxx
from any state
FAULT REACTION
ACTIVE
SW: xxxxxxxxx0xx1111
Fault reaction
completed
FAULT
SW: xxxxxxxxx0xx1000
START
Power-on,
self-initialisation
NOT READY
SW: xxxxxxxxx0xx0000
TO SWITCH ON
Initialised
successfully
CW: xxxxxxxx0xxxx01x
CW: xxxxxxxx0xxxx110
CW: xxxxxxxx0xxxx110
CW: xxxxxxxx0xxxx111
CW: xxxxxxxx0xxxx01x
or
CW: xxxxxxxx0xxxxx0x
CW: xxxxxxxx0xxx0111
CW: xxxxxxxx0xxx1111
CW: xxxxxxxx0xxxx110
Quick stop
completed
CW: xxxxxxxx0xxxx01x
CW: xxxxxxxx0xxxxx0x
CW: Control Word
SW: Status Word
SWITCH-ON
SW: xxxxxxxxx1xx0000
DISABLED
SWITCHED ON
SW: xxxxxxxxx01x0011
READY TO
SW: xxxxxxxxx01x0001
SWITCH ON
OPERATION
SW: xxxxxxxxx01x0111
ENABLED
QUICK STOP
SW: xxxxxxxxx0xx0111
ACTIVE
or
CW: xxxxxxxx0xxxxx0x
or
CW: xxxxxxxx0xxxxx0x
State transition
(0)
(1)
(15)
(2)
(7)
(3)
(6)
(10)
(12)
(9)
(8)
(5)
(4)
(11)