![ABB FEX300 Operating Instruction Download Page 96](http://html1.mh-extra.com/html/abb/fex300/fex300_operating-instruction_3745924096.webp)
Parameterization
96 FEX300,
FEX500
OI/FEX300/FEX500-EN
Menu / Parameter
Value range
Description
Device Info /
Transmitter
Device Version
Indication of the transmitter series (300 HART series,
300 PA series, 300 FF series, 500 HART series, 500
PA series, 500 FF series)
Scanmaster option
Indication whether the ScanMaster option is activated
or not.
For diagnostics or verification, the device can be
checked with a separate tool (ScanMaster). This
option is available for an extra charge and must be
activated in the transmitter.
TX Type
-
Display the transmitter type.
TX Span
-
Calibration value for the transmitter (span)
TX Zero
-
Calibration value for the transmitter (zero)
Offset Iout
Indication of the adjustment value for the current
output (zero).
Gain Iout
Indication of the adjustment value for the current
output (span).
Simulator
Display for service purposes, only.
Transmitter ID
-
ID number of the transmitter.
SAP / ERP No.
-
Order number of the transmitter.
TX Version
Select the "TX Version" submenu.
TX Run Hours
-
Run hours of the transmitter.
Calibration
Select the "Calibration" submenu.
Manufacturer
-
Name of manufacturer
Street
-
Address of manufacturer (street).
City -
Address
(town) of manufacturer.
Phone
-
Phone number of manufacturer
Device Info / Transmitter /
TX Version
TX Firmware Ver.
-
Software version of the transmitter.
TX Hardware Ver.
-
Hardware version of the transmitter.
Com-Controller Ver.
-
Software version of the COM controller.
Bootloader Ver.
-
Software version of the bootloader.
Device Info / Transmitter /
Calibration
First Cal. Date
-
Date of first calibration for transmitter (calibration of
new device).
Last Cal. Date
-
Date of last calibration of transmitter.
Cal. Cert. No.
-
Identification (no.) of the relevant calibration
certificate.
First Cal. Location
-
Place of first calibration for the transmitter.
Last Cal. Location
-
Place of last calibration of transmitter.
italics
= Parameter can only be viewed at the "Advanced" password level.
1) Parameter / menu only available for FEP500 / FEH500.
Summary of Contents for FEX300
Page 169: ...Appendix OI FEX300 FEX500 EN FEX300 FEX500 169...
Page 170: ...Appendix 170 FEX300 FEX500 OI FEX300 FEX500 EN...
Page 175: ......