10.3.1 Transmitter
Warning – Electrical voltage risk!
When the housing is open, EMC protection is impaired and there is no longer any protection
against accidental contact.
• Power to all connecting cables must be switched off.
Fig. 61
Replace the transmitter plug-in as follows:
1.
Switch off supply power.
2.
Open the housing cover (1).
3.
Loosen screws (3) and pull out transmitter plug-in (2).
4.
Replace transmitter plug-in and retighten screws (3).
5.
Close the housing cover (1).
6.