Features
518
System functions and features as of R3.0
syd-0367/1.3 – R3.0 – 03.2013
9. 7. 9
User group: Logging in and logging out
Members of user groups can log themselves out and back in again. The logout and
login procedure can apply simultaneously for all the user groups or specifically for
one user group only.
Detailed Description
Tab. 331 User group
If a member activates a CFU to an external destination, a PISN user or voice mail, he
may automatically be logged out. The response depends on the configuration (see
section
"Call Forwarding Unconditional (CFU) for user group members", page 147
With user groups configured as "large", the UG member is logged out for all types
of redirected calls, even internal ones.
The "Clear configuration" feature (*00 or #00) does not affect the logging in/out of
UG members.
Functions in prefix dialling
Tab. 332 User group: Functions
The logging in/out of UG members is also possible via AMS.
Interface
Operating sequence / signalling on the ter-
minal
Scope
A
• When logging in or out, A obtains an
acknowledgement tone in each case.
• If the function is configured on a key with
LED display, the status logged out/in will be
displayed.
Requirement:
• A is member of one or several user groups
Restriction:
• The last remaining member of a user group
cannot log himself out.
• Does not apply to operator console and gen-
eral bell
Functions
Function codes
Log in to all user groups
*4800
Log out of all user groups
#4800
Log into one user group
*48 <UG No.>
Log out of one user group
#48 <UG No.>