GROUP
NAME
SUPERVISED
SCENARIO
38
Water Sensor
Y
Triggers an alarm when sensor detects presence of water.
NOTE:
flood sensor functionality has not been evaluated by UL/cUL
25
Water Non-Reporting
Y
Used for local alerts. Will not report an alarm to the Central Station
SHOCK SENSOR
GROUP
NAME
SUPERVISED
SCENARIO
13
Shock-Glass-Break
Y
Arms and trips shock sensors immediately when armed to both “Stay” and “Away”
17
Glass-Break-Away Only
Y
Arms and trips shock sensors immediately when armed only to “Away”
Please note:
When selecting “Water” you will see two additional options under “Sensor Sub-Type”. For IQ TempH20 (QS5500-
PO1) & the IQ Flood (QS5516-840/QS5536-840) select “IQ Flood”, for all others, select “Other Flood”
Please note:
When selecting “Shock” you will see two additional options under “Sensor Sub-Type”. For IQ Shock select “IQ
Shock”, for all others select “Other Shock”. *Power G Shock Sensor with prefix 170 o
ff
ers additional sensitivity level functions
WATER
*345 MHz water sensors will have the option to change the “Loop” number to 1, 2 or 3. This will allow
the sensor to be programmed twice as 2 di
ff
erent zones where supported by the device
*345 MHz shock sensors will have the option to change the “Loop” number to 1 or 3. This will allow
the sensor to be programmed twice as 2 di
ff
erent zones where supported by the device
SENSOR GROUPS
Summary of Contents for Qolsys IQ Panel 2
Page 8: ...INSTALLING THE PANEL...
Page 13: ...USER INTERFACE...
Page 17: ...PROGRAMMING...
Page 52: ...SECURITY SENSORS...
Page 84: ...WI FI DEVICES...
Page 91: ...Z WAVE DEVICES...
Page 102: ...BLUETOOTH DEVICES...
Page 110: ...SYSTEM TESTS...
Page 135: ...CUSTOMIZATION...
Page 148: ...MAINTENANCE...
Page 154: ...TROUBLESHOOTING...
Page 164: ...LEGAL...
Page 172: ...SPECIFICATIONS...