WIRING DIAGRAM
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE OF
11
177
NOTE: Use only UL/ cUL listed external siren
in UL/cUL listed installations. Rating:12vDC/
300mA
NOTE: Inputs are used only for residential
Burglary applications. SENSOR 1, 2 & EXT
SIREN are not permissible in UL1610
installations.
IMPORTANT IF USING CUSTOM LENGTH
WIRE:
- 5.5vDC Transformer: Use 18AWG wire no
longer than 25ft to ensure su
ffi
cient power is
received at the panel.
- 7vDC Transformer: Use 18AWG wire no
longer than 100ft to ensure su
ffi
cient power is
received at the panel.
* The minimum permissible wire size shall not
be smaller than 22 AWG
** A 7vDC power supply is only supported on
panels with hardware revision E or newer.
NOTES
5vDC to 7vDC* IN
GND
SENSOR 1
GND
SENSOR 2
GND
EXT SIREN
GND
**WARNING! Use 5vDC to 7vDC**
Power Supply ONLY
4.7k EOL
CLOSED LOOP
CIRCUIT
-
+
EXT SIREN:
Maximum Voltage: 12vDC
Maximum Current: 300mA
5vDC to 7vDC** IN
BARREL JACK
BARREL JACK FOR USE WITH
SUPPLIED BARREL
CONNECTOR CABLE ONLY.
STRIPED WIRE IS POSITIVE (+)
4.7k EOL
Input rating: 100-240vAC, 50/60Hz, 0.2A
Output rating: 5.0 - 7.0vDC, 1.0A
Model SW-055100A or SW-050100A or
SW-070100AB
INSTALLING THE PANEL
Summary of Contents for Qolsys IQ Panel 2
Page 8: ...INSTALLING THE PANEL...
Page 13: ...USER INTERFACE...
Page 17: ...PROGRAMMING...
Page 52: ...SECURITY SENSORS...
Page 84: ...WI FI DEVICES...
Page 91: ...Z WAVE DEVICES...
Page 102: ...BLUETOOTH DEVICES...
Page 110: ...SYSTEM TESTS...
Page 135: ...CUSTOMIZATION...
Page 148: ...MAINTENANCE...
Page 154: ...TROUBLESHOOTING...
Page 164: ...LEGAL...
Page 172: ...SPECIFICATIONS...