GROUP
NAME
SUPERVISED
SCENARIO
10
Entry-Exit- Normal Delay
Y
Gives a period of time to exit the home or to disarm the panel when returning
before sounding the alarm
12
Entry-Exit- Long Delay
Y
Gives a period of time to exit the home or to disarm the panel when returning
before sounding the alarm. This can be a separate delay from the “normal delay”
13
Instant Perimeter D/W
Y
Door or window that triggers an alarm
instantly
when system is armed
14
Instant Interior Door
Y
An interior sensor that triggers an alarm
instantly
while armed to both stay and
away. Does not trip if an entry/exit sensor is tripped first
16
Away Instant- Follower
Delay
Y
Interior door that
triggers alarm instantly
when system is armed to away mode
only
DOOR/WINDOW
IQ Panel 2+ supports PowerG along with ONE “legacy” frequency (319.5 MHz, 345 MHz, or 433 MHz) depending on which RF
daughter card is pre-installed. Sensor Group numbers and behaviors remain the same across all frequencies. When pairing a 345
MHz sensor with the Panel, an additional option for “Loop” number will be shown.
SENSOR GROUPS
SENSOR GROUPS