Protection of the Control Unit:
The local control unit and the local power supply must be protected in one of the following ways:
- The control unit and audible alarm device must be in a protected area which is armed 24 hours a day.
- Each partition must arm the area protecting the control unit and the audible alarm device power supply. This
may require duplicate protection armed by each partition. Access to this protected area, without causing an
alarm, will require that all partitions be disarmed.
- In all cases described above, the protected area for the control unit must be programmed as not-bypassable
User Information:
- The installer should advise the user and note in the User’s Manual
- Service organization name and telephone number
- The programmed exit and entry time
- Instructions to test system weekly
- Note that the installer code cannot arm or disarm the system
- The installer should caution the user not to give system information (e.g., codes, bypass methods, etc.) to casual
users (e.g., service people) and to only give out codes set to expire within 24 hours
-
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE
OF
169
177
UL COMMERCIAL BURGLARY INSTALLATIONS continued…