Wiring Motor Control Board from
Main Control Panel
Blue to brake in
Grey to brake in
Brown to power
Black to power
Motor Control Board
Wiring motor to MCB
Blue to brake out
Grey to brake out
Brown to motor out
Black to motor out
The above 2 motor wires are for right hand motors viewed from the
roller side for a left hand motor swap over brown and black.
If the brown and black wires are to be removed from the board the
curtains must be in the closed position or the bottom bar must be
chocked in the guide channel prior to disconnection, the curtains
will free fall at speed and damage will occur.