Monitoring and Troubleshooting
211
Monitoring and
Troubleshooting
There are several ways to monitor and troubleshoot your RAS 1500.
Show the Settings at
the Interface Level
Use the following command to show the setting at the interface level:
show frame_relay on interface rm0/wan:1 settings
show frame_relay on interface rm0/wan:1 counters
show frame_relay on interface rm0/wan:1 lmi_statistics
Show the Settings at
the PVC Level
Use the following command to show the setting at the PVC level:
show frame_relay pvc <pvc name> settings
List PVC Statistics
Use the following command to display a list of PVC statistics:
show frame_relay pvc <pvc name> counters
List the Status of all
Frame Relay PVCs
Use the following command to list the status of all Frame Relay PVCs:
list frame_relay
Case Study
Goal
Use a Frame Relay link to connect the “sitea” RAS 1500 (located at Site
A) to the “siteb” RAS 1500 (located at Site B).
Assumptions
■
Each site has a functioning RAS 1500.
■
Use the RIPv1 routing protocol.
■
Each site has separate IP network: Site A has 172.16.0.0/B; Site B has
172.17.0.0/B.
■
The Frame Relay service has assigned a DLCI for each site. Site A is
101; Site B is 102.
■
The Frame Relay service provider provides a CIR as negotiated for the
two sites with the service provider.
Strategies
The goals can be achieved in two ways: an unnumbered IP link between
the sites (strategy 1 below) or a numbered IP link between the sites
(strategy 2 below).
Summary of Contents for REMOTE ACCESS SYSTEM 1500
Page 14: ......
Page 40: ......
Page 58: ......
Page 120: ......
Page 130: ......
Page 158: ......
Page 178: ......
Page 202: ......
Page 266: ......
Page 286: ......
Page 292: ......
Page 297: ...INDEX 295 V 90 151 W Windows 95 Dial Up Networking 89 World Wide Web WWW 285 X X 75 152 ...
Page 298: ...296 INDEX ...