Configuring Error Control Options
137
Microcom Networking Protocol Error Control
Microcom Networking Protocol (MNP) is supported by the ITU-T V.42
Recommendation. It was originally developed by Microcom®, Inc. and is
now in the public domain. MNP is based on special protocol frames. If the
remote device does not recognize an MNP Link Request, error control is
not possible.
Error and Flow Control
Flow control of data from the computer is required under error control for
two reasons:
■
The transmitting device buffers a copy of each frame it transmits to
the remote end until it is acknowledged by the receiving device.
■
If errors are encountered, retransmission activity can cause a steady
stream of data from the computer to overflow the buffer.
Error control is required for data compression and recommended for all
calls above 2400 bps.
Cyclic redundancy checking is used to detect errors. An ARQ is issued
when a corrupted data frame is detected, and the data frame is
retransmitted. ARQ denotes error control in U.S. Robotics error control
commands and response codes.
A modem can retransmit a data frame a maximum of twelve times, after
which the modem aborts the call. Disconnection from retry timeout only
occurs under serious line disturbances.
Using Error Control
Disabling Error Control
Action
Command
Default
Disable error control. Not recommended for
calls above 2400 bps.
AT&M0
AT&M4 (Enabled)
Summary of Contents for REMOTE ACCESS SYSTEM 1500
Page 14: ......
Page 40: ......
Page 58: ......
Page 120: ......
Page 130: ......
Page 158: ......
Page 178: ......
Page 202: ......
Page 266: ......
Page 286: ......
Page 292: ......
Page 297: ...INDEX 295 V 90 151 W Windows 95 Dial Up Networking 89 World Wide Web WWW 285 X X 75 152 ...
Page 298: ...296 INDEX ...