![background image](http://html1.mh-extra.com/html/3com/nbx-100/nbx-100_administrators-manual_440814345.webp)
Disk Mirroring
345
Verifying a Failed
Disk Drive
If either disk fails while in a fully mirrored state, the system continues to
operate. The disk LED states described in Table 54 indicate which drive
has failed. In addition, the Disk Status window (Figure 141) in the NBX
NetSet utility shows the status of your disk drives.
Figure 141
Disk Status Window
To verify the status of a disk drive, select
Reports > System Data > Disk
Status
. See the Help for information on verifying disk status.
Synchronizing — disk 1 is valid, disk 0 is
becoming a fully mirrored disk. LED 2 flash rate
indicates progress.
If LED 2 stops normal flashing and intermittently
flashes twice, the mirroring process has failed.
N/A
Flashing
On
On
LED 2 and LED 3 flash alternately: the two disks
are resynchronizing
N/A
Flashing Flashing
On
Synchronized
N/A
On
On
On
Table 54
Disk LED States (continued)