Signaling AAL
365
SSCOP Timers
Table 49 and Table 50 present the SSCOP watchdog timers.
For stability, set the timer No-Response > timer Keep-Alive and timer
No-Response > timer Poll should be set. Also set timer No-Response and
timer CC to a value greater than the round trip delay.
Table 49
SSCOP Timers
SSCOP Timer
Description
Poll
The maximum time between transmission of a POLL PDU, when
SD or SDP PDUs are queued for transmission or are outstanding
pending acknowledgment.
Keep-Alive
Maximum time between transmission of POLL PDUs, when no
SD or SDP PDUs are queued for transmission or are outstanding
pending acknowledgment.
No-Response
Maximum time between receipt of a STAT PDU in an active
connection.
CC
The connection control timer determines the time between
transmission of BGN, END, or RS PDUs, as long as an
acknowledgment PDU has not been received.
Idle
Table 50
SSCOP Timer Default Values
Param name
UNI Standard
Default value
(0.1 sec)
Poll
UNI 3.0
5
Keep alive
UNI 3.0
50
No response
UNI 3.0
500
CC
UNI 3.0
50
Poll
UNI 3.1
45
Keep alive
UNI 3.1
50
No response
UNI 3.1
350
CC
UNI 3.1
50
Idle
UNI 3.1
750
Summary of Contents for CoreBuilder 9000
Page 18: ......
Page 36: ...36 CHAPTER 1 OVERVIEW...
Page 44: ......
Page 152: ...152 CHAPTER 6 MANAGING NETWORK INTERFACES...
Page 224: ...224 CHAPTER 8 VIEWING STATISTICS...
Page 306: ......
Page 320: ...320 CHAPTER 10 ATM NETWORK BASICS...
Page 332: ...332 CHAPTER 11 NETWORK INTERFACE MANAGEMENT...
Page 348: ...348 CHAPTER 12 E IISP PROTOCOL...
Page 374: ...374 CHAPTER 14 ATM SWITCHING...
Page 410: ...410 CHAPTER 16 TRAFFIC MANAGEMENT...
Page 426: ......
Page 450: ...450 APPENDIX D TECHNICAL SUPPORT...
Page 454: ...454 GLOSSARY...