Port Interface Type
147
Update Port Interface
Type
Update the Interface Type (NNI, UNI, or GWY) for a specified port of the
CoreBuilder 9000 ATM Enterprise Switch.
Command Actions
Command Result
Example
Enter:
1 1 3 4 3.1.2 1
The following message is displayed:
This operation will release all connections of the specified
port(s)!
Are you sure (Y/N)?
Enter
y
to confirm. The following message is displayed:
UNI type was set.
The Interface type for port 3.1.2 is updated to UNI.
Enter the menu sequence:
(1) SYS: Platform Configuration
(1) SET: Switch Setup
(3) NNI: NNI Setup
(4) SIF: NNI Set Interface Type
Enter a parameter at the prompt
Parameter
Format or Range
Port number
<slot.group.port> (
0.0
for all ports)
NNI interface type
0
to set interface type to NNI
1
to set interface type to UNI
2
to set interface type to GWY
Direct access sequence:
1 1 3 4
[parameters]
System action taken:
The interface type for the specified port is updated.
System message display:
<type> type was set.
Summary of Contents for CoreBuilder 9000
Page 18: ......
Page 36: ...36 CHAPTER 1 OVERVIEW...
Page 44: ......
Page 152: ...152 CHAPTER 6 MANAGING NETWORK INTERFACES...
Page 224: ...224 CHAPTER 8 VIEWING STATISTICS...
Page 306: ......
Page 320: ...320 CHAPTER 10 ATM NETWORK BASICS...
Page 332: ...332 CHAPTER 11 NETWORK INTERFACE MANAGEMENT...
Page 348: ...348 CHAPTER 12 E IISP PROTOCOL...
Page 374: ...374 CHAPTER 14 ATM SWITCHING...
Page 410: ...410 CHAPTER 16 TRAFFIC MANAGEMENT...
Page 426: ......
Page 450: ...450 APPENDIX D TECHNICAL SUPPORT...
Page 454: ...454 GLOSSARY...