Managing System Alarms
209
New Card
Configured
Configuration data for a new
card is uploaded.
Information only. The card was not
stored in the database.
No Upload Image
Found
Cannot find card image to
upload. Bad code image. (STX)
Download a new code image.
PWR Supply 1
Absent
Power supply #1 is missing or
has failed.
Be sure power supply #1 is plugged in.
Replace the power supply with an
operating unit.
PWR Supply 2
Absent
Power supply #2 is missing or
has failed.
Be sure power supply #2 is plugged in.
Replace the power supply with an
operating unit.
PWR Supply 3
Absent
Power supply #3 is missing or
has failed.
Be sure power supply #3 is plugged in.
Replace the power supply with an
operating unit.
PWR Supply 4
Absent
Power supply #4 is missing or
has failed.
Be sure power supply #4 is plugged in.
Replace the power supply with an
operating unit.
PWR Supply 5
Absent
Power supply #5 is missing or
has failed.
Be sure power supply #5 is plugged in.
Replace the power supply with an
operating unit.
PWR Supply 6
Absent
Power supply #6 is missing or
has failed.
Be sure power supply #6 is plugged in.
Replace the power supply with an
operating unit.
Queue 0 Over
Threshold
The congestion threshold for
Queue 0 was exceeded.
Check and correct VC connections.
Check and adjust VI shaper values.
Check and adjust incoming traffic
volume. Check for faulty IMA links
which may reduce traffic handling for a
group.
Queue 1 Over
Threshold
The congestion threshold for
Queue 1was exceeded.
Check and correct VC connections.
Check and adjust VI shaper values.
Check and adjust incoming traffic
volume. Check for faulty IMA links
which may reduce traffic handling for a
group.
Queue 2 Over
Threshold
The congestion threshold for
Queue 2was exceeded.
Check and correct VC connections.
Check and adjust VI shaper values.
Check and adjust incoming traffic
volume. Check for faulty IMA links
which may reduce traffic handling for a
group.
Queue 3 Over
Threshold
The congestion threshold for
Queue 3 was exceeded.
Check and correct VC connections.
Check and adjust VI shaper values.
Check and adjust incoming traffic
volume. Check for faulty IMA links
which may reduce traffic handling for a
group.
Received External
Alarm 1
User defined.
The leads connected to external alarm
1 have changed from the normal
setting.
Received External
Alarm 2
User defined.
The leads connected to external alarm
2 have changed from the normal
setting.
Received External
Alarm 3
User defined.
The leads connected to external alarm
3 have changed from the normal
setting.
(continued)
Table 41
MCPU and STX Module (System) Alarms (continued)
Alarm
Meaning
Troubleshooting Steps
Summary of Contents for 3C63400-3AC-C - PathBuilder S700 Switch
Page 14: ...xiv CHAPTER SUPPLEMENTARY REGULATORY INFORMATION ...
Page 18: ...4 ABOUT THIS GUIDE ...
Page 28: ...14 CHAPTER 1 SYSTEM DESCRIPTION ...
Page 88: ...74 CHAPTER 3 GETTING STARTED ...
Page 260: ...246 CHAPTER 6 PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING ...
Page 270: ...256 INDEX ...