The STX module provides the following features:
n
Any-to-any port switching
n
Virtual interfaces (VIs); logical UNI ports that provide traffic shaping profiles
(127 total VIs allowed: 24 per triple-slot bus (7-9, 10-12, 13-15, 16-18), 15 per
slot for slots 5 and 6, 1 for MCPU)
n
Deep buffers for queuing (8,000 cells per VI for a total of over 1 million cells
buffered per shelf)
n
Priority queuing in which each VI can be assigned to specific VCs which can be
allocated to one of 4 queues
n
Per VC traffic policing
n
Multicasting (up to 256 connections with 32 leaves)
n
Bipolar Timing Source (BITS) timing clock
n
Per VC statistics
n
4,000 connections per unit
PathBuilder S700
Architecture
The modular architecture of the PathBuilder S700 is designed to accommodate a
wide range of interfaces and support a comprehensive set of applications. The
core component of the unit is a 3.2 Gbps cell bus backplane where all traffic is
carried in the form of ATM cells. The PathBuilder S700 accommodates up to six
power supplies (AC 110/220 VAC and DC-48 VDC) in a load-sharing
configuration.
The overall design philosophy of the PathBuilder S700 is to facilitate the transfer of
cells on and off the bus backplane with enhanced traffic management and
switching capabilities. Figure 1 illustrates the cell bus architecture. All
packet-to-cell segmentation and reassembly (SAR) functions are performed on
each of the application modules (Ethernet, Frame Relay, and CBR), thereby
ensuring efficient cell transfer through the system. Additional SAR power is added
each time a non-ATM interface module is added.
Figure 1
PathBuilder S700 Cell Bus Architecture
Ethernet
Frame
Relay
CBR
ATM
STX
MCPU
10BaseT(2)
T1/E1(4/8)
T1/E1(with integral IMA),
DS3/E3, OC3/STM-1
V.35(4), HSSI(1), T1(8)
10BaseT,RS232, SLIP
Summary of Contents for 3C63400-3AC-C - PathBuilder S700 Switch
Page 14: ...xiv CHAPTER SUPPLEMENTARY REGULATORY INFORMATION ...
Page 18: ...4 ABOUT THIS GUIDE ...
Page 28: ...14 CHAPTER 1 SYSTEM DESCRIPTION ...
Page 88: ...74 CHAPTER 3 GETTING STARTED ...
Page 260: ...246 CHAPTER 6 PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING ...
Page 270: ...256 INDEX ...