148
C
HAPTER
5: C
ONFIGURING
P
ATH
B
UILDER
S700 M
ODULES
, P
ORTS
,
AND
A
PPLICATIONS
Figure 111
IMA Group Status Screen
The IMA Group Status screen lists the following information pertaining to the IMA
status of the group as a whole.
Operation Port(s)
—The port numbers of the active links in the group.
NE State
—The status of the near end group state machine:
not configured
,
startup
,
startupAck
,
unsupported M
,
incompatible symmetry
,
other config abort
,
insufficient links
,
blocked
, or
operational
.
FE State
—The status of the far end group state machine:
not configured
,
startup
,
startupAck
,
unsupported M
,
incompatible symmetry
,
other config abort
,
insufficient links
,
blocked
, or
operational
.
Failure Status
—Failure status of the near end interworking group state machine.
Table 36 lists the possible IMA group failure status conditions.