2N® LiftIP 2.0 User Manual
22
/
119
•
•
•
•
•
Switch control
Connect the switch to the CANCEL terminal.
The
2N
®
LiftIP 2.0
is set to contact control from the factory. Both the jumpers are
mounted on the configuration jumper.
CANCEL can be set to N/C contact too. If the case is a N/C contact, invert the CANCEL input
function in the device web configuration, refer to
Voltage control
DC voltage ranging from 5 to 48 V can be used.
Slide both the jumpers off the configuration jumper link for voltage control.
To use voltage disconnection control
, invert the CANCEL input function in the device web
configuration, refer to
Induction Loop Connection
Follow the applicable regulations while mounting the communicator as they might require that
the induction loop for deaf people should be a mandatory part of a lift cabin communicator
installation. Connect the loop to the
2N
®
LiftIP 2.0
backside connector. Polarity is arbitrary. If
agreed so, the induction loop can be part of the delivery including a 4m cable.
•
Caution
If voltage presence signals a
closed
door, make sure that the power supply is
backed up against power outage.
•
Warning
Keep polarity (see the cover print).