2N® LiftIP 2.0 User Manual
109
/
119
•
CPC (Antenna), P100 2N ext (for alarm calls only)
The protocols work as described in items 3 and 4 for CPC and item 5 for P100. The only
difference is that the audio unit type is transmitted too. Used for alarm calls to the
communicator only.
5.4 Audio Unit Audio Test
The audio unit audio test enables the automatic audio test. It sets a daily / weekly period at a
selected time. If the audio unit is OK, the next checking call will be made. If an error is detected
during the audio test, the next checking call will not be made.
Event after Audio Error
This event informs of an audio test failure. Set the event via the device web configuration, see
. When the audio test is evaluated as unsuccessful, the event is executed (an
operational call is set up
).
Operational call – the call is set up to the number set for the operational call.
5.5 Rescue Process Activation / End
Rescue Process Activation
If an alarm call is set up, the yellow LED keeps shining on the audio unit after the call end. This
indicates the rescue process activation.
Rescue Process End
Call
2N
®
LiftIP 2.0
and enter the rescue end confirming password (
*password*
) during the call
to end the rescue process. Or, press ALARM2 in the lift cabin.
The audio unit announces "Rescue process has been ended" when the rescue process has been
completed.
Set the operation via the web interface, refer to
.
•
•
Warning
If, for example, a call is routed via GSM,
2N
®
LiftIP 2.0
may not detect the DTMF
characters and identify the protocol.
If this happens, we recommend that you change the CPC or P100 settings (3 or 5).