32 / 121
User Manual 3000SP
Rev. 1.1 16/03/2021
Identification: MD-AL-GI-00
Rev. 1.1 of 16/03/2021 - Application: GID
PYLONTECH
CAN port
CANH
pin4
CANL
pin5
RS485 port
485A
pin1 & pin8
485A
pin2 & pin7
Figure 26 – End of Pylontech communication cable with inverter-side terminal in the CAN input
7)
Replace the waterproof cover and secure it with the 4 screws; tighten the cable gland.
8)
Below are some simplified diagrams showing the correct and incorrect installation of the current
sensors.
As shown in the figure, the CTa current sensor must be positioned on the phase wire coming from
the import/export meter so that all the incoming and outgoing power flows can be read.
Figure 27 – Correct positioning of the current sensors
The figure below shows an incorrect positioning of the CTa sensor (consumption reading)