88 / 121
User Manual 3000SP
Rev. 1.1 16/03/2021
Identification: MD-AL-GI-00
Rev. 1.1 of 16/03/2021 - Application: GID
ID98
SDfault
SD card error
Extract the SD card and clean it with a dry cloth.
If the error persists, replace the SD card with a new
one.
ID99
Wi-Fi fault
The Wi-Fi is in error
Contact Technical Support
ID100
BatOCD
Overcurrent
protection of battery
discharge
ID100-ID103 are battery errors.
If the case of occasional errors, wait a few minutes to
see if the error disappears.
If the error persists, contact Technical Support.
ID101
BatSCD
Short circuit
protection of battery
discharge
ID102
BatOV
Battery overvoltage
protection
ID103
BatUV
Battery
undervoltage
protection
ID104
BatOTD
Over-temperature
protection of battery
discharge
ID106-ID107 are battery errors.
Check the conditions of installation and ventilation of
the battery. Alternatively, reduce the charge and
discharge current value set.
If the error persists, contact Technical Support.
ID105
BatOTC
Over-temperature
protection of battery
charge
ID106
BatUTD
Under-temperature
protection of battery
discharge
ID106-ID107 are battery errors.
Check the installation and ventilation conditions of the
battery.
If the error persists, contact Technical Support.
ID107
BatUTC
Under-temperature
protection of battery
charge
10.2.
Maintenance
Inverters generally do not require daily or routine maintenance. In any case, for proper long-term operation
of the inverter, make sure that the heatsink for cooling the inverter has enough space to ensure adequate
ventilation and that it is not obstructed by dust or other items.
Cleaning the inverter
Use an air compressor, a soft dry cloth or a soft-bristled brush to clean the inverter. Do not use water,
corrosive chemicals or aggressive detergents to clean the inverter. Disconnect the AC and DC power to the
inverter before performing any cleaning operations.