40 / 121
User Manual 3000SP
Rev. 1.1 16/03/2021
Identification: MD-AL-GI-00
Rev. 1.1 of 16/03/2021 - Application: GID
Figure 37 – Example of AC switch protecting the inverter
b)
After carrying out these operations, the display of the inverter will come on.
At the time of start-up, the 3000SP inverter requires the following parameters be set:
1) Date and time
8)*Min. discharge voltage (V)
2) Country
9)*Curr. Discharge Max (A)
3) Battery type
10)*Min. voltage threshold
4)*Battery capacity
11)*Discharge depth
5)*Max charge threshold (V)
12)*End-of-discharge V
6)*Max charge current (A)
13)*End-of-charge V
7)*Overvoltage threshold
Note: settings 4)* to 13)* will only be present if the DEFAULT option has been selected.
1)
Date and time
The date/time format of the System is expressed as “Year-Month-Day-Hours-Minutes-Seconds.” Change
the date and time using the “Up” and “Down” keys, press “OK” to confirm and move to the next digit.
Once the setting has been completed, the system will automatically move to the next section.
2)
Country
Select the code corresponding to the national standard (see table below) which can be set using the “Up”
and “Down” keys, press “OK” to move to the next character and confirm. Once the setting has been
completed, the system will automatically move to the next section.