62 / 128
Identification: MD-AL-GI-00
Rev. 1.0 of 21/07/2021 - Application: GID
User’s Manual 1PH 3000TLM-6000TLM-V3
Rev. 1.0 21/07/2021
ID29
ConsistentFault_GFCI
The GFCI sampling value
between the master DSP
and salve DSP is not
consistent
ID30
ConsistentFault_Vgrid
The Grid voltage sampling
value between the master
and salve is not consistent
ID31
ConsistentFault_DCI
3 lines' DCI consistency
error
There are internal faults of
inverter, turn OFF the “DC
switch”, wait for 5 minutes, then
turn ON the “DC switch”. Check
whether the fault is rectified. If
no, please contact technical
support.
ID33
SpiCommFault(DC)
SPI Communication Faulty
(DC side)
ID34
SpiCommFault(AC)
SPI Communication Faulty
(AC side)
ID35
SChip_Fault
Chip Faulty (DC side)
ID36
MChip_Fault
Chip Faulty (AC side)
ID37
HwAuxPowerFault
Auxiliary power fault
ID41
RelayFail
Relay faulty
Please check whether the
resistance to ground of PV string
is too low and whether the
insulation of PV cable is damaged.
If no, please contact technical
support.
ID42
IsoFault
Low isolation faulty
ID43
PEConnectFault
Ground faulty