27 / 128
Identification: MD-AL-GI-00
Rev. 1.0 of 21/07/2021 - Application: GID
User’s Manual 1PH 3000TLM-6000TLM-V3
Rev. 1.0 21/07/2021
3.6.
Installing the 1PH 3000TLM-6000TLM-V3 inverter
1)
Placed the rear panel on the mounting wall, determine the mounting height of the bracket and mark the
mounting poles accordingly. Drilling holes by using Hammer Drill, keep the hammer drill perpendicular
to the wall and make sure the position of the holes should be suitable for the expansion bolts.
2)
Insert the expansion bolt vertically into the hole.
3)
Align the mounting bracket with the position of the holes and fix it to the wall using the most suitable
screws and flat washers, tightening them properly.
4)
Lift the inverter and hang it on the rear panel, and fixing both side of inverter with M6 screw
(accessories).
5)
User can use a lock to block the inverter in case of stealing (Optional).
Figure 7 - Steps for mounting the inverter on the wall