61 / 128
Identification: MD-AL-GI-00
Rev. 1.0 of 21/07/2021 - Application: GID
User’s Manual 1PH 3000TLM-6000TLM-V3
Rev. 1.0 21/07/2021
ID10
GridOVPInstant2
Grid instantaneous
voltage too high 2
ID11
VGridLineFault
Grid Line voltage Faulty
ID12
InvOVP
Inverter overvolatge
ID17
HwADFaultIGrid
The grid current sampling
error
ID18
HwADFaultDCI
The DCI sampling error
ID19
HwADFaultVGrid(DC)
Grid voltage sampling
faulty (DC side)
ID20
HwADFaultVGrid(AC)
Grid voltage sampling
faulty (AC side)
ID21
GFCIDeviceFault(DC)
Current leakage sampling
(DC side)
There are internal faults of
inverter, turn OFF the “DC
switch”, wait for 5 minutes, then
turn ON the “DC switch”. Check
whether the fault is rectified. If
no, please contact technical
support.
ID22
GFCIDeviceFault(AC)
Current leakage sampling
(AC side)
ID23
HwADFaultIdcBranch
Current Branch sampling
faulty
ID24
HwADFaultIdc
DC input current sampling
faulty