36
Atlas Bio Series Access Control Panels Installation Guide
Copyright©2020 ZKTeco USA. All rights reserved.
The available configuration options depend on the Controller model. Each option involves one or more of the
following possibilities. Each possibility determines the functions of the readers connected to the controller. The
configuration can be modified during “
”.
•
In Only
- This is the most common configuration, in which a reader is used to obtain access to enter, but no
credentials are required to exit (although an exit button may be configured for opening the door from the
inside). All controllers will have at least one “
In
” reader. It cannot be configured for another purpose, though
you may choose not to use it.
•
In/Out
- The physical door will have a reader both inside and outside. Authorization is required to access in
either direction.
•
Muster Point
- The reader will serve as a muster point, where users can register that they have reached a
safe location.
•
Card Enrollment Point
- The reader will be used to easily enter the card numbers when adding users.
Page 5: Time Zone (Primary controller Only)
Select your time zone. In most cases you never need to set the actual time; the controller will get the time from
the internet using NTP protocol. Other possibilities are discussed, under “
Review Time Setting (optional)
”.
Note:
The Secondary controllers get their time and time zone from the primary controller.