50
Atlas Bio Series Access Control Panels Installation Guide
Copyright©2020 ZKTeco USA. All rights reserved.
1.
How do I connect two-way doors?
›
Connect “Out” door readers as needed, in pair with “In” door readers according to the following table.
Model
“In” Reader
Pairs with "Out" Reader
1-door
1
2
2-door
1
3
2
4
4-door
1
5 (RS485 connection)
2
6 (RS485 connection)
3
7 (RS485 connection)
4
8 (RS485 connection)
›
Connect door locks and sensors to the port for their “In” door.
›
See “
” in the “Programming Guide” for configuration instructions and additional
options.
2.
What does it mean when I get "Access Denied (Unknown Format)?"
›
Your D0 and D1 wiring might be reversed.
›
The type of card you swiped might not be recognized. See "
" in the
"Programming Guide."
3.
How do I connect a third party reader or a stand-alone reader to an Atlas x60 panel?
›
Connect the wiegand output to the WD0 and WD1 of the stand-alone readers on the panel’s reader port.
Note:
The board can only supply 12V DC, 300mA power so an external power supply may be required.
4.
What kind of wire is recommended for the panel?
›
16 or 18 AWG twisted shielded wire is recommended.
5.
What is the default IP of the panel?
›
169.254.202.242 - This is a "link local" IP address. See "
" in the "Programming Guide"
for link local usage.
6.
How long is the device under warranty?
›
2 Years from original purchase date, replacement/repair of hardware under ZK standard warranty requires an
evaluation of the failed system by a ZK Technical Support specialist, and the issuance of a Technical Support
RMA number.
12. Troubleshooting