4.4 I/O SPECIFICATIONS
Model
Atlas-160
Atlas-260
Atlas-460
Number of
Doors Controlled
One Door
Two Doors
Four Doors
Number
of Readers
Supported
2 (Wiegand Readers) or
2 (OSDP or Fingerprint
Readers)
4 (Wiegand Readers) or
4 (OSDP or Fingerprint
Readers)
4 (Wiegand Readers) or
8 (OSDP or Fingerprint
Readers)
Number of
Inputs
4 (Exit Device, Door
Contact and 2 Aux)
6 (2 Exit Devices, 2 Door
Contacts and 2 Aux)
10 (4 Exit Devices, 4 Door
Contacts and 2 Aux)
Number of
Outputs
2 (1 Form C relay for lock
and 1 Form C relay for
Aux output)
3 (2 Form C relays for locks
and 1 Form C relay for Aux
output)
5 (4 Form C relays for locks
and 1 Form C relay for Aux
output)