background image

46

Atlas Bio Series Access Control Panels Installation Guide

Copyright©2020 ZKTeco USA. All rights reserved.

Adding Secondary Controller manually:

1. 

Click 

 Create 

 on the menu bar. The create controller screen will appear.

2. 

Select a Model.

3. 

Select a Configuration.

4. 

Enter a Name, and select Custom Door Names so you can name the doors in the box, below.

5. 

Enter the Controller's IP Address.

6. 

Leave the Port number as the default, i.e., 443.

7. 

Click 

 Save 

 on the menu bar.

Download and install “

ZK

 

Atlas

” Mobile App from “App Store” or “Google Play Store". 

Before using the mobile App you must authorize mobile through the Web Management Application as shown 
below:

1. 

Go to “

Admin

 

 

Authorized Mobile Devices

10.  Mobile App

Содержание Atlas Bio Series

Страница 1: ...Installation Guide Atlas Bio Series Access Control Panels www zktecousa com Ver 1 0 This installation guide is used for Atlas 160 Bundle Atlas 260 Bundle and Atlas 460 Bundle...

Страница 2: ...ing in operating and maintaining the machine unit equipment It is further essential for safe operation of the machine unit equipment that personnel have read understood and followed the safety instruc...

Страница 3: ...hine unit equipment and such amendments shall not give any right to claim any compensation or damages under any circumstances ZKTeco shall in no way be responsible In case the machine unit equipment m...

Страница 4: ...ined for independent research and development of biometric verification procedures and the productization of biometric verification SDK which was initially widely applied in PC security and identity a...

Страница 5: ...4 4 I O Specifications 16 4 5 Connection Interfaces 16 5 Installation Setup 17 5 1 Installation of Panel Cabinet 17 5 2 Installation Site Diagram 18 6 Connections 19 6 1 Overall Connection Diagram 19...

Страница 6: ...zard 34 4 Connecting the Controller to the Network 39 ReviewTime Settings optional 39 Registration 39 5 Hardware Configuration 40 6 Configuring the Doors 41 Install a Fingerprint Enrollment Reader opt...

Страница 7: ...urce and refer ser vice personnel under the following conditions When cord or connection control is affected When liquid was spilled or an item dropped into the system If exposed to water and or incle...

Страница 8: ...amaged during transport please inform the related agency Please unpack the unit carefully This is an electronic device that must be handled with care in order to avoid damage Do not attempt to put the...

Страница 9: ...stallation Guide Copyright 2020 ZKTeco USA All rights reserved 2 1 OPTIONAL ACCESSORIES Wiegand Card Reader SLK20R Enrollment reader FR1500A FP Prox Reader Prox Card CR10E Card Enrollment Reader Exit...

Страница 10: ...elavailableoutinthemarket Itcancontrolseither one two or four doors and has web based software for monitoring The access control panel is PoE powered and communicates over ethernet TCP IP and also via...

Страница 11: ...egand Reader 3 RESET COMM AUX LED RUN GND PWR NC LOCK1 COM NO SEN GND BUT NC LOCK2 COM NO SEN GND BUT NC LOCK4 COM NO SEN GND BUT NC LOCK3 COM NO SEN GND BUT 12V RS485 READER GND 485B 485A 12V READER1...

Страница 12: ...SHIELD 485A PC 485B GND NC AUX OUT COM NO AUX1 AUX IN GND AUX2 BREAK POW DET GND AC FAIL BAT FAIL PWR RUN COMM1 COMM2 WLAN DOOR 0 1 2345 6 7 8 9 A B C D E F COMM AUX LED RUN GND PWR NC LOCK1 COM NO SE...

Страница 13: ...n 197mm X 171mm Dimensions Cabinet Only 14in X 2 5in X 12in 380mm L X 80mm W X 280mm H Certified Capacity Max User 1 1 or 1 N 5 000 one template per finger Max Template 1 1 or 1 N 5 000 one template p...

Страница 14: ...UT Switching Voltage V 12V 30V Use regulated DC power adaptor only Switching Current A 2 3 Auxiliary relay output Switching Voltage V 12V 30V Use regulated DC power adaptor only Switching Current A 1...

Страница 15: ...PWR RUN COMM1 COMM2 WLAN DOOR 0 1 2345 6 7 8 9 A B C D E F COMM AUX LED RUN GND PWR NC LOCK1 COM NO SEN GND BUT NC LOCK2 COM NO SEN GND BUT NC LOCK4 COM NO SEN GND BUT NC LOCK3 COM NO SEN GND BUT 12V...

Страница 16: ...orm C relay for lock and 1 Form C relay for Aux output 3 2 Form C relays for locks and 1 Form C relay for Aux output 5 4 Form C relays for locks and 1 Form C relay for Aux output Description Related C...

Страница 17: ...R GND 12V READER3 GND D0 D1 RETURN GLED RLED BEEP HOLD SHIELD 12V READER4 GND D0 D1 RETURN GLED RLED BEEP HOLD SHIELD PWR RUN COMM1 COMM2 WLAN DOOR 0 1 2345 6 7 8 9 A B C D E F Cable Conduit Punch hol...

Страница 18: ...ion Guide Copyright 2020 ZKTeco USA All rights reserved Sensor CEILING INDOOR OUTDOOR Atlas x60 Access Control Bundle Electric Lock Exit Button Reader for Out Door Reader for In Door Ethernet Communic...

Страница 19: ...ational Electrical Code ANSI NFPA 70 for Power over communications POE Door Sensor COMM AUX LED RUN GND PWR NC LOCK1 COM NO SEN GND BUT NC LOCK2 COM NO SEN GND BUT NC LOCK4 COM NO SEN GND BUT NC LOCK3...

Страница 20: ...IL 12V POWER GND 12V READER3 GND D0 D1 RETURN GLED RLED BEEP HOLD SHIELD 12V READER4 GND D0 D1 RETURN GLED RLED BEEP HOLD SHIELD PWR RUN COMM1 COMM2 WLAN DOOR 0 1 2345 6 7 8 9 A B C D E F NO AUX1 AUX...

Страница 21: ...ELD 485A PC 485B GND NC AUX OUT COM NO AUX1 AUX IN GND AUX2 BREAK POW DET GND ACFAIL BATFAIL 12V POWER GND 12V READER3 GND D0 D1 RETURN GLED RLED BEEP HOLD SHIELD 12V READER4 GND D0 D1 RETURN GLED RLE...

Страница 22: ...ND D0 D1 RETURN GLED RLED BEEP HOLD SHIELD 12V READER4 GND D0 D1 RETURN GLED RLED BEEP HOLD SHIELD PWR RUN COMM1 COMM2 WLAN DOOR 01 2 3 4 5 6 7 8 9 A B C D EF Wiegand Card Reader 12V READER GND 485B 4...

Страница 23: ...R3 GND D0 D1 RETURN GLED RLED BEEP HOLD SHIELD 12V READER4 GND D0 D1 RETURN GLED RLED BEEP HOLD SHIELD PWR RUN COMM1 COMM2 WLAN DOOR 0 1 2345 6 7 8 9 A B C D E F OSDP Reader OSDP card reader connects...

Страница 24: ...LED BEEP HOLD SHIELD 12V READER4 GND D0 D1 RETURN GLED RLED BEEP HOLD SHIELD PWR RUN COMM1 COMM2 WLAN DOOR 0 1 2345 6 7 8 9 A B C D E F 12V DC 3 FR1500A 2 FR1500A 1 FR1500A 8 FR1500A 12V DC COMM AUX L...

Страница 25: ...2 Set odd numbers for IN reader and even numbers for OUT reader for e g Two readers for one door the RS485 address 1 is for IN reader RS485 address 2 is for OUT reader 3 If FR1500A is powered from Atl...

Страница 26: ...FF ON OFF ON OFF OFF 11 ON ON OFF ON OFF OFF 12 OFF OFF ON ON OFF OFF 13 ON OFF ON ON OFF OFF 14 OFF ON ON ON OFF OFF 15 ON ON ON ON OFF OFF 16 OFF OFF OFF OFF ON OFF 17 ON OFF OFF OFF ON OFF 18 OFF O...

Страница 27: ...F ON OFF ON 41 ON OFF OFF ON OFF ON 42 OFF ON OFF ON OFF ON 43 ON ON OFF ON OFF ON 44 OFF OFF ON ON OFF ON 45 ON OFF ON ON OFF ON 46 OFF ON ON ON OFF ON 47 ON ON ON ON OFF ON 48 OFF OFF OFF OFF ON ON...

Страница 28: ...K POW DET GND AC FAIL BAT FAIL 12V POWER GND 12V READER3 GND D0 D1 RETURN GLED RLED BEEP HOLD SHIELD 12V READER4 GND D0 D1 RETURN GLED RLED BEEP HOLD SHIELD PWR RUN COMM1 COMM2 WLAN DOOR 0 1 2345 6 7...

Страница 29: ...GLED RLED BEEP HOLD SHIELD 485A PC 485B GND NC AUX OUT COM NO AUX1 AUX IN GND AUX2 BREAK POW DET GND AC FAIL BAT FAIL 12V POWER GND 12V READER3 GND D0 D1 RETURN GLED RLED BEEP HOLD SHIELD 12V READER4...

Страница 30: ...HIELD PWR RUN COMM1 COMM2 WLAN DOOR 0 1 2 3 4 5 6789 A B C D E F 485A PC 485B GND NC AUX OUT COM NO AUX1 AUX IN GND AUX2 BREAK POW DET GND AC FAIL BAT FAIL 12V POWER GND 12V READER4 GND D0 D1 RETURN G...

Страница 31: ...31 Atlas Bio Series Access Control Panels Installation Guide Copyright 2020 ZKTeco USA All rights reserved Atlas SeriesWeb Management Application...

Страница 32: ...Check Optional Installations for more details 3 Make sure whether using Network Time Protocol NTP to automatically update the controller s clock over the Internet is possible and acceptable Also make...

Страница 33: ...discussed at the end of this document before proceeding 1 Connect the controller to DC power 2 Connect an Ethernet cable directly from your computer to the controller 3 If your computer is set to use...

Страница 34: ...tion Page 1 Language Choose a language of your choice which will be used for this wizard It will also become the default language of the Web Management Application This can be changed later in the har...

Страница 35: ...llers Page 3 Primary Controller Name Primary controller Only Enter the Name of the controller to display in Web Management Application and reports Note The Secondary controllers are named when they ar...

Страница 36: ...l controllers will have at least one In reader It cannot be configured for another purpose though you may choose not to use it In Out The physical door will have a reader both inside and outside Autho...

Страница 37: ...on Guide Copyright 2020 ZKTeco USA All rights reserved Page 6 Password Primary controller Only Enter a strong password for the primary administrator account The user name for this account is Admin and...

Страница 38: ...IP address and configuration specified by the network administrator Using DHCP is probably the right choice for secondary controllers unless you have a complicated network as discussed below under Sp...

Страница 39: ...d Time Automatically When this box is not checked you can manually set the time by checking Set Server Time to Current Browser Time and clicking Save If you wish to use NTP but with customized NTP ser...

Страница 40: ...on the left shows all controllers At this point you should see one the primary controller Each controller has an I O sub controller listed beneath it The controller manages general controller configu...

Страница 41: ...metric readers the ZKTeco SLK 20R USB fingerprint enrollment reader must be installed at any computer where fingerprints will be enrolled 1 Plug the device into any USB port 2 Install the Fingerprint...

Страница 42: ...ed to the list with a schedule during which access will be granted The default schedule 24 7 provides access at all times Schedules are explained further in the online help 7 Click Save on the menu ba...

Страница 43: ...43 Atlas Bio Series Access Control Panels Installation Guide Copyright 2020 ZKTeco USA All rights reserved...

Страница 44: ...l you created above 3 Click Save on the menu bar The card PIN and fingerprint you entered works to grant access to the specified doors during the specified schedules assuming you chose a compatible De...

Страница 45: ...you should connect and discover controllers one at a time This is the only way you can differentiate them Discovery only works if all controllers are networked on the same subnet If you have a simple...

Страница 46: ...iguration 4 Enter a Name and select Custom Door Names so you can name the doors in the box below 5 Enter the Controller s IP Address 6 Leave the Port number as the default i e 443 7 Click Save on the...

Страница 47: ...stallation Guide Copyright 2020 ZKTeco USA All rights reserved 2 Create and Save an authorization 3 An authorization code will be generated Scan the QR code with the mobile or Right click the image to...

Страница 48: ...ver Address of the primary Atlas Series controller Enter your Atlas Series Username and Password Press Sign In Fig 1 Fig 2 Fig 3 4 Once signed in you will see a list of everything you can do including...

Страница 49: ...anually add these secondary controllers in the Web Management Application Log in and read Manually Adding Secondary Controllers in the help topic Configuration Hardware Adding Controllers Where to Go...

Страница 50: ...recognized See Adding a User and User Test Access in the Programming Guide 3 How do I connect a third party reader or a stand alone reader to an Atlas x60 panel Connect the wiegand output to the WD0...

Страница 51: ...generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guara...

Страница 52: ...Date March 2020 ZKTeco USA a division of ZKTeco 1600 Union Hill Road Alpharetta GA 30005 USA Tel 862 505 2101 www zktecousa com...

Отзывы: