background image

 

 

 

 

    

 

      

KLIC-LG1

 

http://www.zennio.com

 

 

   

                     

Technical Support:

 http://support.zennio.com 

 

33 

204

 

1 Byte

 

I

 

C - - W -

 

DPT_HVACContrMode

 

0 = Auto 
1 = Heat 

3 = Cool 

9 = Fan 

14 = Dry

 

[AC] Mode

 

0 = Automatic; 1 = Heating; 3 = 
Cooling; 9 = Fan; 14 = Dry

 

1 Byte

 

I

 

C - - W -

 

DPT_HVACContrMode

 

0 = Auto 
1 = Heat 

3 = Cool 

9 = Fan 

14 = Dry

 

[AC] Mode

 

3 = Cooling; 9 = Fan; 14 = Dry

 

205

 

1 Byte

 

O

 

C T R - -

 

DPT_HVACContrMode

 

0 = Auto 

1 = Heat 

3 = Cool 

9 = Fan 

14 = Dry

 

[AC] Mode (Status)

 

0 = Automatic; 1 = Heating; 3 = 
Cooling; 9 = Fan; 14 = Dry

 

1 Byte

 

O

 

C T R - -

 

DPT_HVACContrMode

 

0 = Auto 
1 = Heat 

3 = Cool 

9 = Fan 

14 = Dry

 

[AC] Mode (Status)

 

3 = Cooling; 9 = Fan; 14 = Dry

 

206

 

1 Bit

 

I

 

C - - W -

 

DPT_Heat_Cool

 

0/1

 

[AC] Simplified Mode

 

0 = Cooling; 1 = Heating

 

207

 

1 Bit

 

O

 

C T R - -

 

DPT_Heat_Cool

 

0/1

 

[AC] Simplified Mode (Status)

 

0 = Cooling; 1 = Heating

 

208

 

1 Bit

 

I

 

C - - W -

 

DPT_Switch

 

0/1

 

[AC] On/Off

 

0 = Off; 1 = On

 

209

 

1 Bit

 

O

 

C T R - -

 

DPT_Switch

 

0/1

 

[AC] On/Off (Status)

 

0 = Off; 1 = On

 

210

 

1 Bit

 

O

 

C T R - -

 

DPT_Bool

 

0/1

 

[AC] Internal Error: Control

 

Unable to Control the AC

 

211

 

1 Bit

 

O

 

C T R - -

 

DPT_Bool

 

0/1

 

[AC] Internal Error: Communication

 

Unable to Set AC Communication

 

212

 

1 Bit

 

O

 

C T R - -

 

DPT_Bool

 

0/1

 

[AC] AC Unit Error: Active Error

 

AC Unit Error

 

213

 

14 Bytes

 

O

 

C T R - -

 

DPT_String_ASCII

 

0/1

 

[AC] AC Unit Error: Error Code

 

See AC Unit Manual

 

214

 

1 Byte

 

I

 

C - - W -

 

DPT_Scaling

 

0% - 100%

 

[AC] Speed: Percentage Control

 

0 % = Automatic; [0.4...25.1] % = S1; 
[25.5...50.2] % = S2; [50.6...75.3] % 
= S3; [75.7...100] % = S4

 

1 Byte

 

I

 

C - - W -

 

DPT_Scaling

 

0% - 100%

 

[AC] Speed: Percentage Control

 

0 % = Automatic; [0.4...33.3] % = S1; 
[33.7...66.7] % = S2; [67.0...100] % = 
S3

 

1 Byte

 

I

 

C - - W -

 

DPT_Scaling

 

0% - 100%

 

[AC] Speed: Percentage Control

 

[0.4...25.1] % = S1; [25.5...50.2] % = 

S2; [50.6...75.3] % = S3; [75.7...100] 
% = S4

 

1 Byte

 

I

 

C - - W -

 

DPT_Scaling

 

0% - 100%

 

[AC] Speed: Percentage Control

 

[0.4...33.3] % = S1; [33.7...66.7] % = 
S2; [67.0...100] % = S3

 

215

 

1 Byte

 

O

 

C T R - -

 

DPT_Scaling

 

0% - 100%

 

[AC] Speed: Percentage Control (Status)

 

Automatic = 0 %; S1 = 25 %; S2 = 50 
%; S3 = 75 %; S4 = 100 %

 

1 Byte

 

O

 

C T R - -

 

DPT_Scaling

 

0% - 100%

 

[AC] Speed: Percentage Control (Status)

 

Automatic = 0 %; S1 = 33.3 %; S2 = 
66.7 %; S3 = 100 %

 

1 Byte

 

O

 

C T R - -

 

DPT_Scaling

 

0% - 100%

 

[AC] Speed: Percentage Control (Status)

 

S1 = 25 %; S2 = 50 %; S3 = 75 %; S4 
= 100 %

 

Содержание KLIC-LG1

Страница 1: ...KLIC LG1 KNX RYB for LG A C Units USER MANUAL ZCL LG1 Application program version 1 1 User manual edition 1 1 _a www zennio com...

Страница 2: ...ation 5 1 3 Start Up and Power Loss 6 2 Configuration 7 2 1 General 7 2 2 Inputs 10 2 2 1 Binary Input 10 2 2 2 Temperature Probe 11 2 2 3 Motion Detector 11 2 3 Logic Functions 12 2 4 A C Gateway 13...

Страница 3: ...upport http support zennio com 3 DOCUMENT UPDATES Version Changes Page s 1 1 _a Changes in the application program Improved unit connection process 1 0 _c Clarification about the meaning of the LED gr...

Страница 4: ...and periodically sent to the KNX bus to inform other devices The most outstanding features of KLIC LG1 are Bidirectional control of LG A C units through the connection wires provided by LG R supply v...

Страница 5: ...into the programming mode making the associated LED 1 light in red Note if this button is held while plugging the device into the KNX bus the device will enter into safe mode The LED will blink in red...

Страница 6: ...fer to the device Datasheet bundled in the device packaging and also available at http www zennio com 1 3 START UP AND POWER LOSS Depending on the configuration some specific actions will be performed...

Страница 7: ...specific to KLIC LG1 i e all the functions related to interfacing with the A C unit and to the management of the climate control system ETS PARAMETERISATION After importing the corresponding database...

Страница 8: ...objects are available by default AC On Off and AC On Off Status allow switching on value 1 and off value 0 the A C unit or reading the current status respectively AC Temperature Setpoint and AC Temper...

Страница 9: ...om Technical Support http support zennio com 9 AC Reference Temperature Status shows the temperature that is being used by the A C unit as reference See section 2 4 1 for further options Several error...

Страница 10: ...older models of the Zennio motion detector e g ZN1IO DETEC and ZN1IO DETEC N will not work properly with KLIC LG1 ETS PARAMETERISATION When Inputs has been activated in the General parameters screen...

Страница 11: ...n the KLIC LG1 product section at the Zennio website www zennio com Notes The ZN1IO DETEC P motion detector is compatible with a variety of Zennio devices However depending on the device it is actuall...

Страница 12: ...cution of each function can depend on a configurable condition which will be evaluated every time the function is triggered through specific parameterizable communication objects The result after exec...

Страница 13: ...ictions in Fan and Dry modes it is not possible to change the setpoint Temperature setpoint which can be modified within a specific range of values depending on the capabilities of the specific A C un...

Страница 14: ...vent Scenes which allows defining specific climate control presets to be sent to the machine on the reception of scene orders from the KNX bus These functionalities imply changes in the state of the A...

Страница 15: ...tion window under AC Gateway provides the following parameters Figure 6 A C Gateway Configuration CONTROL CONFIGURATION Figure 7 A C Gateway Configuration Control Configuration Configuration Master Sl...

Страница 16: ...the A C unit operation mode There will be only taken in account values that are appropriated with some of available modes in LG units which are represented in Table 1 AA Mode status 1 Byte object whi...

Страница 17: ...alue 0 when the mode switches to Cooling or to Dry or the value 1 when it switches to Heating The Fan mode is not reflected in the value of this object FAN Fan enables the Fan function See section 2 4...

Страница 18: ...are enabled several objects to modify them at run time will be available The values of this objects will be restricted to an interval which is defined by the absolute limits established by the A C un...

Страница 19: ...shing an initial operating time value Periodic Sending resending period in hours of operating time If set to 0 the periodic send is disabled When operating time object reaches its maximum value 65535...

Страница 20: ...Off Delay The sending of the value 0 disables the automatic off functionality Note switch on orders sent to the A C unit from a wired remote control have a higher priority than the Auto Off mode INITI...

Страница 21: ...AMETRISATION After enabling this function the menu on the left will show a new tab named Speeds containing the following parameters Figure 15 A C Gateway Speeds Number of Fan Speeds allows specifying...

Страница 22: ...ic and AC Speed Automatic Status 1 Bit objects which will let activating deactivating the automatic mode or reading the current status respectively Automatic Speed Object Polarity sets the polarity of...

Страница 23: ...deactivating the swing function or reading its current status respectively Direct Positioning enables the AC Horizontal Flaps Percentage Control 1 byte object which allow setting the position of the f...

Страница 24: ...objects are incorporated into the project topology to allow activating or deactivating such mode and consulting whether it is currently active respectively Vertical Flaps enables the AC Vertical Flaps...

Страница 25: ...eters Mode Last Heating Dry Cooling Fan or Automatic Fan Speed Last Automatic if the automatic fan speed control is available or any of the available fan speeds 1 4 Horizontal Flaps Last Swing Swirl o...

Страница 26: ...ION After enabling this function see section 2 4 1 a new tab named Scenes will be incorporated to the tab tree It allows setting up different scenes up to 5 consisting each of them in a set of orders...

Страница 27: ...nd 32 C Note this initial setpoint value may be modified by the setpoint limits during runtime 2 4 6 ERROR HANDLING KLIC LG1 is capable of managing two error types Communication or internal errors err...

Страница 28: ...ors is detected the corresponding object will be sent with a value of 1 to the KNX bus Once the error is over it the object will be sent with a value of 0 Errors in the AC machine AC AC Unit Error Act...

Страница 29: ...x Result 1 Byte Unsigned 2 Bytes O C T R DPT_Value_2_Ucount 0 65535 LF Function x Result 2 Byte Unsigned 4 Bytes O C T R DPT_Value_4_Count LF Function x Result 4 Byte Signed 1 Byte O C T R DPT_Scaling...

Страница 30: ...0 63 128 191 Ix Short Press Run Scene Sending of 0 63 1 Byte C T DPT_SceneControl 0 63 128 191 Ix Short Press Save Scene Sending of 128 191 1 Bit I O C T R W DPT_Switch 0 1 Ix Switch Sensor Edge Sendi...

Страница 31: ...x Long Press Light On Sending of 1 On 1 Bit C T DPT_Switch 0 1 Ix Long Press Light Off Sending of 0 Off 1 Bit I C T W DPT_Switch 0 1 Ix Long Press Light On Off Switching 0 1 1 Byte C T DPT_SceneContro...

Страница 32: ...ording to parameters 115 144 173 1 Bit I C W DPT_Switch 0 1 Ix Presence Day Night According to parameters 116 145 174 1 Bit O C T R DPT_Occupancy 0 1 Ix Presence Occupancy State 0 Not Occupied 1 Occup...

Страница 33: ...Error Control Unable to Control the AC 211 1 Bit O C T R DPT_Bool 0 1 AC Internal Error Communication Unable to Set AC Communication 212 1 Bit O C T R DPT_Bool 0 1 AC AC Unit Error Active Error AC Uni...

Страница 34: ...utomatic Off Speed 1 1 Automatic On 1 Bit I C W DPT_Switch 0 1 AC Speed Automatic 0 Automatic On 1 Automatic Off Speed 1 224 1 Bit O C T R DPT_Switch 0 1 AC Speed Automatic Status 0 Automatic On 1 Aut...

Страница 35: ...n and send us your inquiries about Zennio devices http support zennio com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 www zennio com info zennio c...

Отзывы: