Note
:
even if this option is not enabled, the status objects may be sent to the
KNX bus if the initial configuration differs from the current status of the A/C
machine
.
2.4.5
SCENES
The Scenes function allows defining a set of statuses (in terms of On/Off, mode, fan
speed, etc.) that KLIC-LG1 will send to the A/C unit whenever it receives the
corresponding scene values from the KNX bus.
ETS PARAMETRISATION
After enabling this function (see section 2.4.1), a new tab named Scenes will be
incorporated to the tab tree. It allows setting up different scenes (up to 5), consisting
each of them in a set of orders to be sent to the A/C unit upon the reception, through the
KNX bus and by means of the
“
[AC] Scene
” object, of the corresponding scene value
(decreased by 1, according to the KNX standard).
For every enabled scene (
Scene
n
), the particular parameters that should be configured
are:
Figure 18: Scenes.
Scene number
: sets the scene number (1-64) that, upon reception through the
“
[AA] Scene
” object (decreased by one), will trigger the corresponding orders,
as defined next.
On/Off
: “No change”, “On” or “Off”.