KLIC-LG1
http://www.zennio.com
Technical Support:
http://support.zennio.com
16
Reference Temperature (Status)”
are available when KLIC has been
parameterized as master.
Important
: the master device has to be connected before plugging the slave
device.
OPERATION MODES
KLIC-LG1 allows controlling the A/C unit operating mode through the following objects,
available by default:
“[AC] Mode”
: 1-Byte object which allows selecting the A/C unit operation
mode. There will be only taken in account values that are appropriated with
some of available modes in LG units, which are represented in
Table 1.
“[AA] Mode (status)”
: 1-Byte object which allows knowing the A/C unit
operating mode status.
Object Value
A/C unit mode
0
Auto
1
Heating
3
Cooling
9
Fan only
14
Dry
Table 1. A/C unit operating modes.
In addition, it can be enabled by parameter:
Heat Mode Available:
if this checkbox is unchecked, the options relative to
heat mode, automatic mode, maximum setpoint limit and simplified mode will
disappear.
Figure 8: A/C Gateway. Configuration. Operation Modes.