Zennio GetFace IP
Tecnical Support
51
SIP Registration Lost.
Device Rebooted.
Tamper Switch Activated.
SIP Registration Lost Message
: sets the e-mail subject and the e-mail body
to be sent in the event of SIP registration lost. HTML format symbols can be
used to edit e-mail body.
Device Rebooted Message
: similar to the previous parameters.
Tamper Activated Message:
similar to the previous parameters.
3.2.3.2
AUTOMATION
Automation
allows associating system events (key presses, RFID card readings,
changes in a digital input, etc.) with specific actions (digital output activations, user
audio playback, calls, etc.). Moreover, the action execution can be restricted by
selected conditions (time profiles, input status, etc.).
Up to
five functions
can be set, which can be configured in an interface available by
clicking on the 'Edit' button of the corresponding function (represented by a pencil
icon). Each function combines events, actions and conditions. Up to 30 conditions can
be configured.
Figure 44
Automation.
Note:
After the device initialization, the status of the inputs will be automatically
checked in the Automation.