Zennio GetFace IP
Tecnical Support
23
Figure 14
Switches.
Regarding the configuration, it is necessary to enable the switch in the top side box and
to set the page options according to the provided lock system.
Basic Settings
of the switches:
Switch Mode
: sets the opening mode (
monostable
, in case it gets
automatically deactivated some time after the opening order; or
bistable
, if
a manual deactivation is required).
Switch-On Duration
: delay for monostable switches.
Controlled Output
: regarding the output type, it can be configured as a
relay or as an electric ou
tput. In case of selecting “None”, the switch will be
controllable through HTTP commands.
Output Type:
the output behaviour can be configured as one of the
following types
Normal
: to perform the door opening, the output needs to be activated.
Inverted
: to perform the door opening, the output needs to be
deactivated.