Alarm Levels
National safety standards for gas exposures vary from country
to country and, consequently, it is normal practice to specify
alarm levels at the time of order. Typical alarm levels set in the
Minigas Mk5 are listed below, but the instrument has a facility
(referred to as Field Settable Alarm mode) which allows the
user to change certain of the factory-set alarm points.
UK
USA
Oxygen INST
Deficiency 19%
Deficiency 19.5%
Enrichment 23%
Enrichment 23.5%
Explosive INST
20% LEL
10% LEL
(methane in air)
(methane in air)
Toxic INST
CO
400ppm
CO
200ppm
H
2
S
40ppm
H
2
S
20ppm
Cl
2
5ppm
Cl
2
5ppm
SO2
10ppm
SO
2
8ppm
CO
2
0.5% VOL
CO
2
2.0% VOL
Toxic STEL(15min)
CO
200ppm
CO
100ppm
H
2
S
15ppm
H
2
S
15ppm
Cl
2
2ppm
Cl
2
2ppm
SO
2
5ppm
SO
2
5ppm
CO
2
0.5% VOL
CO
2
1.0% VOL
Toxic LTEL(8hr)
CO
30ppm
CO
35ppm
H
2
S
10ppm
H
2
S
10ppm
Cl
2
1ppm
Cl
2
1ppm
SO
2
2ppm
SO
2
2ppm
CO
2
1.5% VOL
CO
2
0.5% VOL
7. SPECIFICATIONS