2. USING THE MINIGAS MK5
2.10 WATCHDOG SIGNAL
2.10.1 General
When the Minigas Mk5 is operating normally in a safe gas
environment and no alarms and warnings have occurred
previously then, as a confidence check, a watchdog signal
recurs at 10-second intervals. This signal consists of a brief
audio bleep accompanied by a short flash on the green indicator
lights. However, this signal is modified to a double bleep after
any alarm condition has occurred and been cancelled or if the
battery voltage is low (see Table 1).
2.10.2 Silent Watchdog Facility
A software option is available allowing the watchdog signal to
be muted (that is, visible only):
(1)
In the Display Mode, apply short or medium presses to the
I/O button to step through to the elapsed time screen.
(2)
Apply a medium press to the
O button to obtain the
bLEEP -y n- prompt screen.
(3)
Press the
O button (no) to mute the watchdog bleep
and return to the elapsed time screen.
To revert to the normal audible and visible watchdog, repeat
the above procedure, pressing the I/O (yes) button when the
bLEEP -y n- prompt is displayed.
2.11 GO/NOGO MODE
A Minigas Mk5 configured with the Go/NoGo software option
does not display any gas readings. Instead, under safe
conditions it has the INST (
) arrow highlighted and only
displays indications of the sensors fitted: